This is the manual for clusterctl v0.3.0. The latest release is v0.4.0: read its manual.
clusterctl fabric state

clusterctl fabric state

clusterctl fabric state

Check whether the fabric ports of a node set are up

Synopsis

Ask the fabric about each node’s port.

A port is up only when its logical link state is Active. A port that is physically linked but still Initialize or Armed has no subnet manager configuration yet and carries no traffic, so it is reported down, with both states shown. A port the fabric does not answer for is reported as such. Any port that is not up makes the command fail.

clusterctl fabric state -n exe[1-10]

clusterctl fabric state [NODESET] [flags]

Options

  -h, --help   help for state

Options inherited from parent commands

      --config strings      configuration file or directory to read, repeatable (default: CLUSTERCTL_CONFIG or the search path)
      --context string      context to act on (default: the current one)
      --dry-run             report what would be done and change nothing
      --fanout int          how many hosts to work on at once, at least 1 (default: from the configuration)
      --force               allow protected hosts, and nodes the inventory does not know, to be touched
  -n, --nodes stringArray   node set to act on, for example 'exe[1-10],@rack:R02' (default: CLUSTERCTL_NODES)
  -o, --output string       output format: table, wide, json, yaml, nodeset, name, jsonpath=, jq= (default "table")
      --set stringArray     override one configuration value as PATH=VALUE, repeatable
  -y, --yes                 answer the confirmation prompts with yes

SEE ALSO